Products / Genvinset®
Genvinset®

Genvinset® MTHFR A1298C

Kit for detecting the A1298C polymorphism of the MTHFR gene by Real Time PCR using TaqMan® probes technology

Information about the product

Methylenetetrahydrofolate reductase (MTHFR) is a key enzyme in folate metabolism. Although MTHFR protein does not participate in the clotting cascade as other proteins such as FII and FV (and therefore belonging to the well-known group of coagulation factors), the involvement of MTHFR in the folate metabolic pathway may affect thrombophilia development, as well as increased cancer risk or Alzheimer’s disease appearance.

MTHFR gen can present different polymorphisms. The most common and studied variant is the MTHFR C677T polymorphism but, also, the MTHFR A1298C mutation has been studied. The frequency of both MTHFR polymorphisms differs among the different ethnicities.

 

INTENDED USE

Genvinset® MTHFR A1298C is a semi-automated kit for the in vitro qualitative detection of the A1298C polymorphism (NCBI dbSNP rs1801131; NM_001330358.2:c.1409A>C) in the Methylene tetrahydrofolate reductase (MTHFR) gene (OMIM: 607093) associated with thrombophilia risk in genomic DNA extracted from whole blood using Real Time PCR technology with specific TaqMan® probes.

Patients who can benefit from this determination are those referred by a specialist. The results of this test should not be the only ones on which the therapeutic decision is based and should be used as an aid in the diagnosis together with results of other markers of the disease.

The intended user of the kit is technical personnel trained to carry out the protocol and the interpretation of results described in the instructions for use.

 

 

WORKFLOW

 

RESULTS

 

Limitations

  • Mutations or polymorphisms at annealing primer/probe sites are possible and may result in the lack of allele definition. Other technologies could be necessary to resolve the typing.
  • Data and result interpretation should be revised by qualified personnel.
  • This product is an auxiliary tool for the diagnosis of patients with suspected thrombophilia. Use these results in conjunction with clinical data and results of other tests performed on the patient.

Downloads

Log in to see the product files.

Related products

Kit for multiplex detection of the -675 PAI-1 4G/5G polymorphism at SERPINE1 gene and rs5985 (Val34Leu) at the F13A1 gene by real-time PCR using TaqMan® probes technology.
Kit for multiplex detection of both A1298C and C677T polymorphisms in the MTHFR gene by real-time PCR using TaqMan® probes technology.
Kit for detecting C282Y and H63D mutations in the HFE gene by real-time PCR using TaqMan® probes technology
Kit for detecting the G20210A mutation of the prothrombin (FII) gene and the G1691A mutation of the Factor V (FV) gene by Real-Time PCR using TaqMan® probes technology
Kit for the detection of deltaF508 mutation in CFTR gene by real-time PCR technology using TaqMan® probes technology.
Kit for the detection of HLA-DQA1*05 allele by Real-Time PCR technology using TaqMan® probes technology.
Kit for detection of the -675 4G/5G polymorphism in SERPINE1 gene by Real Time PCR using TaqMan® probes technology
Kit for detecting the G20210A mutation of the prothrombin gene by Real Time PCR using TaqMan® probes technology
Kit for detecting the G1691A mutation of the Factor V (FV) gene by Real Time PCR using TaqMan® probes technology
Kit for detecting the C677T polymorphism of the MTHFR gene by Real Time PCR using TaqMan® probes technology
Kit for detecting the C282Y mutation of HFE gene by Real Time PCR using TaqMan® probes technology
Kit for detecting the H63D mutation of HFE gene by Real Time PCR using TaqMan® probes technology
Kit for detecting the S65C mutation of HFE gene by Real Time PCR using TaqMan® probes technology